Skip to content
Home Circuitry HQ
SHEET 01 · Reference index35 guides · NEC-aware
Search

Search Home Circuitry HQ

4-Way Switch Wiring Diagram: Control One Light From Three Places

By Reviewed by Home Circuitry HQ Editorial Team Last reviewed Published on Category: Switches And Lighting, Blog

A 4-way switch goes between two 3-way switches to control one light from three or more places. It has no COM terminal: two IN terminals take the travelers from one 3-way and two OUT terminals send them to the other. In one position it passes the travelers straight through, in the other it swaps them. Cut the power and test before opening any box.

A hallway with a ceiling light and one white toggle switch with a closed cover plate

Belongs to the guide: 3-Way Switch Wiring Diagram and Step-by-Step Install Guide

Electrical Safety & YMYL Disclaimer: This guide provides general electrical information and is not a substitute for a licensed electrician or your local authority having jurisdiction (AHJ). Electrical work can cause fire, severe shock, and death. Always turn off the circuit breaker and verify the circuit is dead with a voltage tester before opening a switch box. A switch that is off is not a dead box. ESFI strongly recommends hiring a qualified, licensed electrician for electrical work, and the CPSC advises the same. Verify which NEC edition and local amendments apply in your area.

A 4-way switch is the middle piece of a multi-location lighting circuit. If you can already wire two switches, read our 3-way switch wiring diagram guide first, then use the interactive 4-way diagram to click through three, four or five locations.

What does a 4-way switch do?

A 4-way switch lets a third (or fourth, or fifth) location control a light that two 3-way switches already control. It has four traveler terminals and no COM terminal. Two of the terminals are marked IN and two OUT. In one position it connects each IN terminal to the OUT terminal straight across; in the other it crosses them, swapping the two travelers. That swap is what lets any switch flip the light state, whatever position the others are in.

The layout: two 3-ways with a 4-way in the middle

The circuit has a fixed order:

  1. First 3-way switch: the hot feed lands on its dark COM screw. Its two traveler screws connect to the traveler pair running onward.
  2. One or more 4-way switches: the travelers from the previous switch land on the IN pair and the travelers leaving land on the OUT pair.
  3. Last 3-way switch: its two traveler screws take the travelers from the last 4-way, and its COM screw sends the switched hot to the light.

Between each pair of boxes the cable carries the two travelers and a neutral, plus a ground, which is typically 3-wire cable with ground. The power-at-switch and power-at-light layouts differ in where the feed enters, and the 4-way sits in the traveler run in either one. Travelers are shown in black and red in our diagram, but colours are conventions, not code: identify real conductors by testing.

The switching rule

The hot enters on one traveler. Each crossed 4-way swaps it to the other traveler, and the light is on when the hot is on the traveler the last 3-way has chosen. Written as a rule: the light is on when entry position + exit position + the number of crossed 4-ways is an even number. With one 4-way, flipping any of the three switches toggles the light. The interactive diagram lists every combination for up to five locations.

Wiring steps

These steps summarise the manufacturer’s instructions and are not instructions for your house.

  1. Turn off power at the breaker and test. Leviton’s sheet says to turn off power at the circuit breaker or fuse and test that it is off before wiring. Test every box you open.
  2. Identify the wires. If you are replacing an old 4-way, identify the IN and OUT wires before you remove the device, as the sheet cautions. Mark each pair with tape.
  3. Connect the travelers. Land the pair from the first 3-way on the IN terminals and the pair going toward the last 3-way on the OUT terminals. Swapping the two wires within a pair only changes which position of the switch counts as straight, not which locations control the light, but keeping the same colours on the same side keeps the logic readable.
  4. Fasten the terminals. Leviton’s sheet says to loop wires clockwise about three quarters of a turn on the terminal screws and tighten firmly, and that the terminals take up to #10 AWG copper.
  5. Connect the ground to the green screw and to the box if the box is metal.
  6. Mount, restore power and test from every location.

Box fill for the 4-way box

A switch box can be crowded, and NEC 314.16 limits how many conductors fit. Each conductor counts by AWG volume from Table 314.16(B) (2.00 cubic inches for 14 AWG, 2.25 for 12 AWG). Each device yoke counts twice (314.16(B)(4)), and all equipment grounding conductors together count once (314.16(B)(5)). Cable clamps inside the box add one more allowance (314.16(B)(2)).

For an illustration, take a 4-way box in a run with two 14/3 cables, with the travelers terminating on the switch and the two neutrals spliced together:

  • 4 traveler conductors + 2 neutrals = 6 conductors × 2.00 = 12.00 in³
  • Equipment grounds: one allowance = 2.00 in³
  • 4-way switch yoke: 2 × 2.00 = 4.00 in³
  • Total: 18.00 in³

Table 314.16(A) lists a 3 × 2 × 3½ in. metal device box at 18.0 in³. So that box is exactly full with no internal clamps, and over the limit with them. In 12 AWG the same count is 6 × 2.25 + 2.25 + 4.50 = 20.25 in³, so a larger box is needed. This example uses our arithmetic on the cited table values. Your boxes, cables and local rules may differ, so ask a licensed electrician or inspector.

Troubleshooting

  • Light works from two switches but not the third: a pair of travelers is on the wrong terminals at a 4-way, or a traveler is on a 3-way COM screw.
  • Lights act backwards: an IN pair and an OUT pair are mixed up, or the travelers are crossed in a box.
  • Light stays on or off regardless: a hot feed or switched leg is on the wrong wire. This is a reason to stop and call a licensed electrician rather than keep testing live conductors.
  • Warm switch plate, buzzing or scorching: stop and shut off the circuit. Our guide to the signs that mean call a licensed electrician lists them.

For a fuller fault-finding list, see 3-way switch wiring troubleshooting.

Dimmers and smart switches on a 4-way circuit

A dimmer or smart switch in a multi-location circuit follows its own instructions: often one dimmer plus standard or companion switches, a neutral at the dimmer box, and an LED-compatible load. Check the box before buying, and use the dimmer switch guide for LED wattage and compatibility. For the basics of every switch type, see understanding switches.

When to call a licensed electrician

Call one when the boxes hold unfamiliar or old wiring, aluminum or knob-and-tube conductors, no neutral in boxes where you want a smart switch, or when you cannot identify the travelers. A permit and inspection may apply where you live. Treat this page and the diagrams as a way to understand the circuit, not as instructions for your wall.

Answers to common questions

How many 4-way switches can I use with two 3-way switches?

As many as you have locations for. Every 4-way you add puts one more place in the middle of the traveler run, so one gives three places, two give four and three give five. The logic is the same each time: the two 3-ways stay at the ends and each 4-way either passes the travelers through or swaps them. The practical limits are box fill and cable runs.

Is a 4-way switch the same as a 3-way switch?

No. A 3-way has a COM terminal and two travelers, and it picks one traveler. A 4-way has two IN and two OUT terminals and no COM, and it connects the pairs straight or crossed. A 4-way cannot replace a 3-way, because the circuit needs a COM terminal at each end, one for the hot feed and one for the wire to the light.

Which wires go on the IN and OUT terminals of a 4-way switch?

Land the two travelers that come from one 3-way switch on the IN pair, and the two travelers that run on to the other 3-way on the OUT pair. If you are replacing an old 4-way, identify which pair is IN and which is OUT before you take the old switch out, as the Leviton sheet advises. Marking each wire with tape helps.

Why does my 4-way circuit work from some switches but not others?

The usual cause is travelers landed on the wrong terminals: a traveler on a 3-way COM screw, or the IN and OUT pairs mixed up on a 4-way. Switches that work in some positions and not others point to a swapped pair. Turn the breaker off, confirm it is dead with a tester and recheck each box, or call a licensed electrician.

Can I put a dimmer on a 4-way circuit?

Usually yes, but follow the dimmer maker's instructions. Many LED dimmers work in a multi-location circuit only as the single dimmer, with standard or companion switches at the other locations, and some need a neutral. Do not put two electronic dimmers on one circuit unless the instructions say so. Our dimmer guide covers compatibility and LED wattage limits.

Can I wire a 4-way switch myself?

Replacing a like-for-like switch is a common DIY job, but a 4-way circuit has several boxes and many conductors, and a mistake can cause a fire or shock. ESFI strongly recommends hiring a qualified, licensed electrician for electrical work, and your local authority decides whether a permit is needed. If the boxes do not match a diagram, stop and call one.

Evidence and sources

  1. Leviton: 4-Way Switches, Cat. No. 5604, installation instructions (PK-93029-10-02-0A) (leviton.com)
  2. Leviton: Lever Edge 3-way switch installation instructions (E5603) (leviton.com)
  3. NFPA 70 (NEC) 2020 text as reproduced in the 2022 California Electrical Code: Table 314.16(A), Table 314.16(B), 314.16(B)(4) and (B)(5) (law.resource.org)
  4. ESFI: Do-It-Yourself (DIY) Electrical Safety (esfi.org)
  5. CPSC: Plug into Safety! (NSN 18-07) (cpsc.gov)

More on this topic

Up to the top